About ClimateGuard Sliding Stacking Apartment Door

Darley’s Climateguard Sliding Stacking Apartment Door provides a high performance, energy efficient sliding and stacking door solution that is both functional and contemporary.
Ideal for high end commercial developments and apartments, it structural design allows for extra large door panels and a glass thickness of 24mm.

This Sliding Stacking Apartment door is entirely thermally broken and provides high performance energy values, whilst maintaining a competitive level of wind and water performance.

Design Features:

  • null
    Accepts glass thickness from 24mm – 30mm
  • null
    Compatible with other Darley Aluminium Commercial Systems
  • null
    Compatible with various Darley mainframe options
  • null
    Thermally broken system for higher performance energy values
  • null
    Clean covers available to hide thermal strips if necessary
  • null
    Tested and approved by an independent NATA accredited laboratory
  • null
    Maximum recommended panel sizes of 2700mm x 1500mm
  • null
    Maximum recommended panel weight of 300kg (dependent on rollers and operational force)

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.

Download CAD Drawings

Please note: file will be in .zip format.

About

About ClimateGuard Sliding Stacking Apartment Door

Darley’s Climateguard Sliding Stacking Apartment Door provides a high performance, energy efficient sliding and stacking door solution that is both functional and contemporary.
Ideal for high end commercial developments and apartments, it structural design allows for extra large door panels and a glass thickness of 24mm.

This Sliding Stacking Apartment door is entirely thermally broken and provides high performance energy values, whilst maintaining a competitive level of wind and water performance.

Design Features:

  • null
    Accepts glass thickness from 24mm – 30mm
  • null
    Compatible with other Darley Aluminium Commercial Systems
  • null
    Compatible with various Darley mainframe options
  • null
    Thermally broken system for higher performance energy values
  • null
    Clean covers available to hide thermal strips if necessary
  • null
    Tested and approved by an independent NATA accredited laboratory
  • null
    Maximum recommended panel sizes of 2700mm x 1500mm
  • null
    Maximum recommended panel weight of 300kg (dependent on rollers and operational force)
Wers Ratings

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

Testing

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.

Technical Manuals
CAD Drawings

Download CAD Drawings

Please note: file will be in .zip format.

Videos

Specifications

Commercial Hardware

Related Products

Let’s Start To Connect With Darley Today

null
null
Menu

Login

Register Now Forgot Password ?