About ClimateGuard 100mm Centre Double Glazed Framing System

The ClimateGuard 100mm x 60m Centre Double Glazed framing system is an ideal choice for commercial buildings and high end residential developments and apartments. This thermally broken system utilises high end polyamide thermal break strips to achieve superior energy ratings.

This energy efficient system is also easy to fabricate and can be used in conjunction with other ClimateGuard systems including ClimateGuard Sliding Stacking Apartment Door and ClimateGuard Awning & Casement window.

It has also been tested and exceeds Australian Standard AS2047, in an independent NATA approved laboratory.

Design Features:

  • null
    Accepts glass thickness from 24mm – 36mm
  • null
    Compatible with other Darley Aluminium Commercial Systems
  • null
    Compatible with various Darley mainframe options
  • null
    Thermally broken system for higher performance energy values
  • null
    Tested and approved by an independent NATA accredited laboratory

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.

Download CAD Files

Please note: file will be in .zip format.

About

About ClimateGuard 100mm Centre Double Glazed Framing System

The ClimateGuard 100mm x 60m Centre Double Glazed framing system is an ideal choice for commercial buildings and high end residential developments and apartments. This thermally broken system utilises high end polyamide thermal break strips to achieve superior energy ratings.

This energy efficient system is also easy to fabricate and can be used in conjunction with other ClimateGuard systems including ClimateGuard Sliding Stacking Apartment Door and ClimateGuard Awning & Casement window.

It has also been tested and exceeds Australian Standard AS2047, in an independent NATA approved laboratory.

Design Features:

  • null
    Accepts glass thickness from 24mm – 36mm
  • null
    Compatible with other Darley Aluminium Commercial Systems
  • null
    Compatible with various Darley mainframe options
  • null
    Thermally broken system for higher performance energy values
  • null
    Tested and approved by an independent NATA accredited laboratory
Wers Ratings

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

Testing

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.

Technical Manuals
CAD Drawings

Download CAD Files

Please note: file will be in .zip format.

Specifications

SystemMaximum weight per panelMaximum height per panelMaxiumim Width per panelGlass ThicknessTest Report No.Water Rating (Pa)Structural (Pa)Ultimate (Pa)
Climateguard Centre Glazed Commercial Framing 100mm2400mm1200mm12-36mm0545.1860015003000

Commercial Hardware

Related Products

Let’s Start To Connect With Darley Today

null
null
Darley 2024-2025 Christmas Closure Dates

Login

Register Now Forgot Password ?